45° Non Mydriatic Retinal Camera With the CR-1 MkII you can obtain high quality and high resolution diagnostic images in a very easy way. A minimum pupil diameter of only ø 4.0 mm (ø 3.7 mm in Small Pupil mode) is required.
2X digital zoom Besides the true 45 degree image , a 2 x digital magnification provides a magnified image of the retina for viewing the details of the area of interest.
Low flash mode Ultra low Flash Intensity for more patient comfort and faster examinations. The low flash intensity will make it possible to make faster examinations since the pupil almost does not shrink after the flash. So it will be possible to re- take photo’s or to take photos of both eyes in rapid sequence almost immediately. Especially beneficial when photographing elderly persons, who take long time to dilate again.
It will be easier to perform stereo photography ; when taking the 2 images for the stereo pair in rapid succession is very important. Otherwise the patient will cannot remain fixed on the target and the stereo effect will be poor .
And importantly the patients’ discomfort will be reduced ; your patients will appreciate the ultralow flash mode of the Mark II. It is even essential in case of patients with photophobia.
High quality retinal imaging Canon’s expertise in the field of imaging technology and optics has resulted in the CR-1 MkII exceptional digital retinal imaging capabilities Combined with a EOS Digital SLR, the high resolution images can help the detection and monitoring of ocular conditions such as diapvetic retinopathy, glaucoma and macular degeneration.
EOS camera The CR-1MkII is currently equipped with the EOS 50D with 15.1 Megapixel resolution. It could easily be exchanged for a future successor model, so you will not miss out on any future advancement in digital cameras.
Ergonomic design with intuitive controls The CR-1 MKII is very compact and lightweight. The compact size reduces anxieties of patient against photography. With its short reaching distance it is easy for the photographer to observe the patient’s eye(s), to check the status of dilated pupil. The Illuminated Operation Panel, enables easy operation in darkened rooms . The motorized chinrest makes it very easy to align the patient’s eye to the correct height.
Bundled Retinal Imaging Control Software The CR-1 MkII comes with Canon's Retinal Imaging Control Software (RICS) for full camera control and image optimalization The software has extensive diagnostic tools for optimized workflow and patient management. e.g. Cup/Disc ratio calculation, compare studies, RGB channel display, stereo viewing
Open connectivity and DICOM compliant The CR-1MkII with RICS has extensive network capabilities and is fully DICOM compliant.
|